Compact Power Logo
Compact Power - Company History

Powerhouse Prodigy Troubleshooting Techniques

RC-50

Problem: Flow from hydraulic pump erratic or non-existent.

Probable cause:
1. Hydraulic system oil level low.
2. Damaged or blocked suction line.
3. Worn or chipped pump gears.
4. Worn or broken drive shaft or coupling.


Back To Top